Vue de la page 221
CUSTOMATCOMMANDS
HSPA+ATCommandsReferenceGuide 222
<sendDataMode> Datamodeforsendingdataincommandmode(AT#SSEND).
0 Datarepresentedastext.Default:0.
1 Datarepresentedassequenceofhexadecimalnumbers(from00toFF).
EachoctetofthedataisgivenastwoIRAcharacterlonghexadecimalnumber.
Notes
Youmustsettheparameterswith#SCFGEXTbeforeestablishingadataconnectionusingtheAT+SGACT
command.
Thesevaluesareautomaticallysavedinnonvolatilememory.
KeepaliveisavailableonlyonTCPconnections.
ForthebehaviorofAT#SLandAT#SLUDPincaseofautoresponsemodeorincaseofnoautoresponsemode,
seethedescriptionofthetwocommands.
Examples
Socket1setwithdataviewsring,textdatamode,akeepalivetimeof30minutesandlistenautoresponseset.
Socket3setwithdataamountsring,hexrecvdatamode,nokeepaliveandlistenautoresponsenotset.
Socket4setwithhexrecvandsenddatamode
at#scfgext?
#SCFGEXT: 1,2,0,30,1,0
#SCFGEXT: 2,0,0,0,0,0
#SCFGEXT: 3,1,1,0,0,0
#SCFGEXT: 4,0,1,0,0,1
#SCFGEXT: 5,0,0,0,0,0
#SCFGEXT: 6,0,0,0,0,0
OK
SocketConfigurationExtended2#SCFGEXT 2
Setcommandsetsthesocketconfigurationextendedparametersforfeaturesnotincludedin#SCFGEXT
command.
Readcommandreturnsthecurrentsocketextendedconfigurationparametersvaluesforallthesixsockets,inthe
format:
#SCFGEXT2:<connId1>,<bufferStart1>,0,0,0,0<CR><LF>
...
#SCFGEXT2:<connId6>,<bufferStart6>,0,0,0,0<CR><LF>
Testcommandreturnstherangeofsupportedvaluesforallthesubparameters.